- Working voltage: DC5V-DC30V (wide voltage anti-connection protection)
- Trigger signal source: high-level trigger DC 3.0V—24V signal ground and system ground to improve the system’s anti-interference ability can also short-circuit the ground
- Output capacity: DC DC 5V–36V, continuous current 15A at normal temperature, power 400W!!! Under the condition of auxiliary heat dissipation, the maximum current can reach 30A
- Product size: 64mm*35mm*19.3mm
- Mounting hole: diameter 3mm
- Working temperature: -40 ° C ~ 85 ° C
- P1 mode: After the signal is triggered, the MOS transistor turns on the OP time and then turns off; in the OP time, the following operation
- P1.1: The signal is triggered again.
- P1.2: Signal triggers re-timed again
- P1.3: The signal triggers reset again, the MOS tube is disconnected, and the timing is stopped.
- P-2: Give the trigger signal, after the MOS transistor is disconnected from the CL time, the MOS transistor turns on the OP time. After the timing is completed, the MOS transistor is disconnected.
- P3.1: Give the trigger signal, after the MOS transistor turns on the OP time, the MOS tube turns off the CL time, then loops the above action, the signal is given again in the loop, the MOS tube is disconnected, the timing is stopped; the number of cycles (LOP) can be set.
- P3.2: No need to trigger signal after power-on, MOS tube turns on OP time, MOS tube disconnects CL time, loops the above action; loop number (LOP) can be set
- P-4: Signal hold function If there is a trigger signal, the timing is cleared, the MOS transistor remains on; when the signal disappears, the MOS transistor is disconnected after timing the OP; during the timing, there is a signal and the timing is cleared.
- ON : MOS tube is allowed to conduct during OP conduction time
- OFF : MOS tube is disabled, always off
- Short press the STOP button on the main interface to switch between ON and OFF. The current state will flash, then return to the main interface. This function is the emergency stop function. One button is used to open and close the MOS tube.
- Sleep mode (long press the stop button to view the current mode)
- C-P sleep mode: within five minutes, without any operation, the digital tube automatically turns off the display, the program runs normally.
- O-d normal mode: the digital tube is always on display
- Press and hold the STOP button for 2 seconds and then release to switch the C-P and O-d states. The current state will flash and then return to the main interface.
Customer –
There is a size difference on the electronics board and pins between the item with the box and without.
S***y –
Вместе с этим таймером заказал таймер с релейным выходом. В итоге пришли два таймера, и оба с релейным выходом.
V***k –
Пришел, работает. Проверял только режим 1.1
V***v –
20 дней в Испанию, быстро, проверил-всё работает, спасибо, вы лучшие
R***s –
Доставка 18 дней до Воронежской .супер
N***l –
Produit d’un bon rapport qualité prix livré en 34 jours après la commande Produit très bien emballé et bien fini
Z***e –
33 дня до мадрид. пока еше не пробоваль на рабочеспасобность. спасибо. попробую добавлю отзыв
G***k –
доставка месяц в Калининград. В работе не проверял.
J***d –
Quick shipping awesome
M***i –
vendeur sérieux
S***a –
A aparência é ótima, ainda vou testar.
F***o –
excelente produto, só me confundi com a voltagem.
K***r –
ПОЛУЧИЛ
J***s –
Excelente calidad precio. Viene completo. con 6 configuraciones. mediante un pulsador con descarga. y uno que es sin carga ni pulsador. perfecto para casi todo lo que imagines. Retardo, tiempo de luz encendida, etc.